Chapter 14 Snapshots
168
Snapshot Operations in the Flexi Pad Control Block
1
In the M/E-1 bank Flexi Pad control block, press the [SNAPSHOT] button.
This allocates the Flexi Pad control block to snapshot operations. The
numeric display shows the last selected bank number and the register
number last recalled on the bank.
2
Select the bank for recall.
See step 3 (page 166) in “Saving a snapshot with the Flexi Pad control
block.”
3
To apply temporary attributes, press the following buttons, turning them
on.
a) When Xpt Hold mode is selected in setup.
b) When Key Disable mode is selected in setup.
For details of temporary attributes and available attributes, see “Snapshot
Attributes” in Chapter 1 (Volume 1).
Notes
The cross-point hold and key disable settings are maintained until you
next press the [XPT HOLD] button.
Applying temporary attributes does not affect the contents of the
register.
4
Press the button in the memory recall section which shows the desired
register name.
The button you pressed lights yellow, and this recalls the snapshot.
The numeric display shows the selected register number after the bank
number.
To cancel a snapshot recall operation
After recalling a snapshot, to cancel the recall, press the [UNDO] button.
Control block Temporary
attribute to apply
Button
Cross-point control
block
A/B bus cross-point
hold
[XPT HOLD] button in the
background A/B bus
Key cross-point hold
[XPT HOLD] button in the key bus
a)
Key disable
[XPT HOLD] button in the key bus
b)
Flexi Pad control
block
Effect dissolve [EFF DISS] button
Auto transition [AUTO TRANS] button