Sony 2 Water Dispenser User Manual


 
253Setup Relating to Switcher Processor
Chapter 16 Engineering Setup
7
In the <Bus> group, select any of the following.
Enable: Enable the GPI link setting for the selected bus.
Disable: Disable the GPI link setting for the selected bus.
All Enable: Enable the GPI link setting for all buses.
To set the delay value
Use the following procedure.
1
In the GPI Link Adjust menu, turn the knobs to select the output port for
which you want to set the delay value, and the corresponding delay value.
2
Press [Delay Set].
This confirms the delay value, which is reflected in the status area.
Interfacing With External Devices (Device Interface
Menu)
To carry out setup relating to connections with external devices, display the
Switcher>Device Interface menu.
To display the Device Interface menu
In the Engineering Setup menu, select VF3 ‘Switcher’ and HF7 ‘Device
Interface.’
Making 9-pin port device interface settings
The description in this section takes the REMOTE3 port as an example. For
other REMOTE ports, carry out the same process as required.
1
In the Switcher>Device Interface menu, press [Remote Assign].
The Remote Assign menu appears.
Knob Parameter Adjustment Setting values
4 Bus Bus selection 1 to 112
Knob Parameter Adjustment Setting values
1 GPI Port GPI output port for the
setting
1 to 8
5 Delay Delay value for the output
port
0 to 300 (fields)