223Setup Relating to Operations From the Control Panel
Chapter 16 Engineering Setup
Making control panel GPI input settings
Use the following procedure.
1
In the Panel>Device Interface menu, press [GPI Input].
The GPI Input menu appears.
2
Using any of the following methods, select the settings.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob to make the setting.
3
In the <Trigger Type> group, select the trigger type.
: Apply the trigger on a rising edge of an input pulse.
: Apply the trigger on a falling edge of an input pulse.
: Apply the trigger on a change in the polarity of the input signal.
(Level): Carry out the specified operation when the input is low or
high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1, M/E-2, M/E-3, P/P: Set the action for one of the operating banks.
Common/Setup: Set an action for something other than the above, or a
setup action.
5
Using any of the following methods, select the action to be set.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs to make the setting.
a) • Action list when the trigger type is other than “Level”
Knob Parameter Adjustment Setting values
1 Port Port selection 1 to 8
Knob Parameter Adjustment Setting values
2 Action Action selection
1 to ...
a)
5 Reg No Register number
1 to 4
b)
1 to 99
c)
1 to 399
d)