279Setup Relating to Router Interface and Tally
Chapter 16 Engineering Setup
Level: Specify the level in the S-Bus space.
a) When the matrix size is Standard, the maximum value is 889. For the Compact size, the
maximum value is 897.
b) When the matrix size is Standard, the maximum value is 887. For the Compact size, the
maximum value is 897.
Making an external box setting
Use the following procedure.
1
In the Router/Tally>Router menu, press [External Box Assign].
The External Box Assign menu appears.
The status area shows the external box size, address, and other settings.
2
In the <Device> group, select what the setting applies to (External Box 1
to 4).
3
In the <Matrix Size> group, select the number of inputs.
No Assign: Do not use.
8×1: Select an external box with 8 inputs and 1 output.
16×1: Select an external box with 16 inputs and 1 output.
32×1: Select an external box with 32 inputs and 1 output.
4
Turn the knobs to make adjustments.
a) When Matrix Size is 8×1
b)When Matrix Size is 16×1
c) When Matrix Size is 32×1
To couple external boxes
By coupling a number of external boxes, the number of inputs can be increased.
Here the example of coupling External Box1 and External Box2 is described.
Knob Parameter Adjustment Setting values
1 Source Source start address
1 to maximum value
a)
2 Destination Destination start address
1 to maximum value
b)
3 Level Level 1 to 8
Knob Parameter Adjustment Setting values
1 Source Source start address
1 to 1017
a)
1 to 1009
b)
1 to 993
c)
2 Destination Destination start address 1 to 1024
3 Level Level 1 to 8