255Setup Relating to Switcher Processor
Chapter 16 Engineering Setup
(Level): Carry out the specified operation when the input is low or
high.
No Operation: Apply no trigger on an input pulse.
4
In the <Target> group, select the action block.
M/E-1, M/E-2, M/E-3, P/P: Set the action for one of the operating banks.
Common/Setup: Set an action for something other than the above, or a
setup action.
5
Using any of the following methods, select the action to be set.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs to make the setting.
a) • Action list when the trigger type is other than “Level”
When Target is M/E-1, M/E-2, or M/E-3: Cut, Auto Trans
Key1 Cut, Key1 Auto Trans, Key2 Cut, Key2 Auto Trans, Key3 Cut, Key3 Auto
Trans, Key4 Cut, Key4 Auto Trans
SS ? Recall, Key1 SS ? Recall, Key2 SS ? Recall, Key3 SS ? Recall, Key4 SS ?
Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is P/P: Cut, Auto Trans
DSK1 Cut, DSK1 Auto Trans, DSK2 Cut, DSK2 Auto Trans, DSK3 Cut, DSK3
Auto Trans, DSK4 Cut, DSK4 Auto Trans
FTB Cut, FTB Auto Trans
SS ? Recall, DSK1 SS ? Recall, DSK2 SS ? Recall, DSK3 SS ? Recall, DSK4 SS
? Recall
Effect ? Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, KF Reverse
Run, No Action
When Target is Common/Setup: FM Src1 Field Freeze, FM Src1 Frame Freeze, FM
Src2 Field Freeze, FM Src2 Frame Freeze
FM Src1 Freeze Off, FM Src2 Freeze Off
User1 to 8 SS ? Recall, User1 to 8 EFF ? Recall, User1 to 8 EFF ? Recall & Run,
User1 to 8 KF Run, User1 to 8 KF Stop, User1 to 8 KF Rewind, User1 to 8 KF
Reverse Run, No Action
• Action list when the trigger type is “Level”
When Target is M/E-1, M/E-2, M/E-3, or P/P: Aspect, No Action
When Target is Common/Setup: Format, Aspect, No Action
b) When knob 3 selection is “Key Snapshot”
c) When knob 3 selection is “Snapshot” or “Effect”
6
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
Knob Parameter Adjustment Setting values
3 Action Action selection
1 to ...
a)
4 Reg No Register number
1 to 4
b)
1 to 99
c)