Section 2
2-3
10 TO 20 BY 2 TA ST C15X40
1 2 TA ST MC8X20
Double Channels
Back to back double channels, with or without spacing between
them, are available. The letter D in front of the section name will
specify a double channel.
21 22 24 TA D MC9X25
55 TO 60 TA D C8X18
Angles
Angle specifications in STAAD are different from those in the
AISC manual. The following example illustrates angle
specifications.
L 40 35 6 = L 4 x 3-1/2 x 3/8
Angle symbol Thickness in 1/16th
inch
10 times length 10 times length of
of one leg in inch other leg in inch
Similarly, L505010 = L 5 x 5 x 5/8 and L904016 = L 9 x 4 x 1
At present, there are two ways to define the local y and z-axes for
an angle section. To make the transition from the AISC Manual to
the program data easy, the standard section for an angle is
specified:
51 52 53 TA ST L40356
This specification has the local z-axis (i.e., the minor axis)
corresponding to the Z-Z axis specified in the steel tables. Many