STAAD Commands and Input Instructions
Section 5
5-414
5.51.5 Concrete Design Terminator
Purpose
This command must be used to terminate the concrete design.
General format:
END CONCRETE DESIGN
Description
This command terminates the concrete design, after which normal
STAAD commands resume.
Example
START CONCRETE DESIGN
CODE ACI
FYMAIN 40.0 ALL
FC 3.0 ALL
DESIGN BEAM 1 TO 4 7
DESIGN COLUMN 9 12 TO 16
DESIGN ELEMENT 20 TO 30
END
Notes
Without this command, further STAAD commands will not be
recognized.