STAAD Commands and Input Instructions
Section 5
5-372
In this example, member forces will be printed for all load cases,
whereas loading 1 and 3 will be used for printing support reactions
and code-checking of all members.
Notes
The LOAD LIST command may be used for multiple analyses
situations when a re-analysis needs to be performed with a selected
set of load cases only. All load cases are automatically active
before the first CHANGE command is used.
After a CHANGE command has been used anywhere in the data, it
is good practice to specify the LOAD LIST command after an
ANALYSIS command and before the next command; otherwise
only the last set of cases analyzed will be used in the design.
Do not enter this command within the loads data (from the first
Load command in an analysis set down to the associated Analysis
command).