Section 5
5-121
…
LOAD 2
…
LOAD 3
…
LOAD 4
…
LOAD 5
REPEAT LOAD
…
PERFORM ANALYSIS
CHANGE
LOAD LIST ALL
PRINT …
PRINT …
PARAMETER
…
CHECK CODE …
FINISH
MEMBER TENSION 0
This command switches off ALL tension/compression only
specifications for load cases which are specified subsequent to this
command, usually entered after a CHANGE command. There is no
list associated with this command. Hence, for any further primary
load cases, the tension/compression only attributed is disabled for
ALL members.
Notes
a) See Section 5.5 for explanation of the SET NL command. The
number that follows this command is an upper bound on the total
number of primary load cases in the file.
b)
STAAD performs up to 10 iterations automatically, stopping if
converged. If not converged, a warning message will be in the
output. Enter a SET ITERLIM i command (i>10) before the first
load case to increase the default number of iterations. Since