STAAD Commands and Input Instructions
Section 5
5-366
BEGIN HARMONIC FORCE
FREQ FLO 3.5 FHI 33 NPTS 5 MODAL FLIST 4 5 10 -
17 21 30
HARMONIC FORCE DAMP .033
JOINT LOAD PHASE X 0.0 PHASE Y 10.0 PHASE Z 15.0
UNIT KIP
10 5 TO 7 BY 2 88 FX 10.0 FY 5.0
UNIT POUND
10 5 TO 7 BY 2 -
88 FX 10.0 FY 5.0
COPY LOAD
1 1.5 2 0.8 -
3 1.0
AMPLIT ALL A 0.10 B .21
PRINT HARMONIC DISP ALL
END
STEADY STATE NOTES:
For members, the final results at the joints will be complete but the
section results will be as if the member loads were applied as
statically equivalent loads at the member ends.