6 - 32 6 - 32
MELSOFT
6 COMMUNICATION SETTING EXAMPLES OF THE UTILITY SETTING TYPE
(4) Setting the logical station number (Setting on communication setting
wizard)
Logical station number setting will be described using the example for using the
Built-in Ethernet port CPU (Q04UDEH) system example for (1).
1) Start the communication setup utility and select the
communication setting wizard.
2) Type "17" in Logical station number and click Next>
.
Carry out either of the following two ways of steps of the
programmable controller side settings.
Follow 3) and 4) of steps in case of connection by specified
Host (IP address).
Follow 5) and 6) of steps in case of Ethernet port direct
connection.
3) Make settings as indicated below and click Next>
.
PC side I/F : Ethernet board
Connect module : CPU module
Protocol : TCP
Time out : 60000
4) Make settings as indicated below and click Next>
.
PLC side I/F : CPU module
Host (IP Address) : 10.97.19.177
Step7)
5) Make settings as indicated below and click Next> .
PC side I/F : Ethernet board
Connect module : CPU module
Protocol : UDP
Time out : 60000
(To the next page)