Mitsubishi Electronics SW3D5C-ACT-E Frozen Dessert Maker User Manual


 
6 - 109 6 - 109
MELSOFT
6 COMMUNICATION SETTING EXAMPLES OF THE UTILITY SETTING TYPE
(c) Q series-compatible C24, L series-compatible C24
Using the Q series-compatible C24 or L series-compatible C24 requires a
sequence program to set the following buffer memory addresses.
The following table indicates the buffer memory
addresses that must be set and the sequence program.
Setting Item (Buffer Memory Address)
Settings
Modem connection channel designation (2EH)
0: Not connected (modem function is not used)
1: CH1 side interface
2: CH2 side interface
Initialization data No. designation (34H) *1
0
H: Send of initialization data specified in the sending user
registration frame specifying area
7D0
H to 7D4H: Initialization data No.
GX Developer connection designation (36H)
0: Not connected
1: Connected.
Callback function designation (2001H)
0H: Auto line connect
1
H: Callback connect (Fixation)
3
H: Callback connect (Number specification)
7
H: Callback connect (Number specification (max. 10 units))
9
H: Auto line connect (Callback fixation)
B
H: Auto line connect (Callback number specification)
F
H: Auto line connect
(Callback number specification (max. 10 units))
*1: The following initialization data are factor-registered to the Q series-
compatible C24.
When the modem used corresponds to the initialization data (7D0
H to
7DA
H), specify the following registration number.
When using the modem where the initialization data have not been
registered, register the AT command to the buffer memory address
(1B00
H) of the Q series-compatible C24.
Registration No. Corresponding Device
Hexadecimal Decimal
Initialization Command
Maker Type
7D0H 2000 ATQ0V1E1X1\J0\Q2\V2\N3S0=1 Aiwa
PV-AF2881WW
PV-BF288M2
7D1H 2001 ATQ0V1E1X1\Q2\V2\N3S0=1 Micro General Laboratory
MC288XE
MC288X1
7D2H 2002 ATQ0V1E1X1&K3\N3S0=1 Microcom
DESKPORTE22.8S
DESKPORTE33.6S
7D3H 2003 ATQ0V1E1X1&H1&R2&A3&D2S0=1 Omron ME3314B
7D4H 2004 ATQ0V1E1X1\J0\Q2\N3S0=1 Sun Electronic MS336AF
7D5H 2005 ATE1Q0V1&C1&D2&H1&I0&R2&S0S0=1 Omron ME5614B
Sun Electronic MS56KAF
Micro General Laboratory MRV56XL
7D6H 2006 ATE1Q0V1&C1&D2&K3&S0S0=1
VS-2621A
7D7H 2007 ATE1Q0V1&C1&D2&K3&S1S0=1
Matsushita Electric
VC-173
7D8H 2008 ATE1Q0V1&C1&D2&K3&S0S0=1 Omron MT128B -D
7D9H 2009 ATE1Q0V1&C1&D1\Q2&S0S0=1 Sun Electronic TS128JX
7DAH 2010 ATE1Q0V1&C1&D2\Q3&S0S0=1 Sharp DN-TA1
7DCH
2012 AT&S0S0=1
7DDH
2013 ATX1&S0S0=1
General
*Use this device for operation check.
If the device does not operate, create the
initialization command, which matches the