Mitsubishi Electronics SW3D5C-ACT-E Frozen Dessert Maker User Manual


 
APP - 61 APP - 61
MELSOFT
A
PPENDICES
(c) Workaround
To workaround this problem, change the DEP configuration and the linker
option (recreate the program).
1) Possible to change the linker option and create user
applications
Select "Image is not compatible with DEP (/NXCOMPAT:NO)" in
[Linker]-[Advanced]-[Data Execution Prevention (DEP)] in the MFC
project Property Pages, and create user applications.
Configure DEP as follows.
Execution environment DEP configuration
Windows Vista
R
,
32-bit Windows
R
7
Windows
R
XP
Other than AlwaysOn
(When AlwaysOn:
Change to OptIn,
When other than AlwaysOn:
No change necessary)
2) Impossible to change the linker option
When the linker option cannot be changed (when programs cannot be
recreated), configure DEP to "AlwaysOFF".
Execution environment DEP configuration
Windows Vista
R
,
32-bit Windows
R
7
Windows
R
XP
AlwaysOff