8 ACCESSIBLE DEVICES AND RANGES
8.8.2 Accessible ranges
This section indicates the accessible ranges for CC-Link G4 communication.
(1) Configuration
IBM-PC/AT com
p
atible
1
Connected
station CPU
CC-Link
module
Relayed
module
2Relayed network
3
Relayed
module
Relay target
CPU
CC-Link
G4 module
(2) Accessibility list
The following table indicates whether access can be made or not.
The connected station CPUs are all accessible.
Whether the relay target CPU is accessible or not is indicated by
(accessible)
or
(inaccessible).
(a) When CC-Link G4 module is in Q mode or LCPU
3. Relay Target CPU
1. Connected Station CPU
(Usable control name)
2. Relayed Network
QCPU
(Q mode)
Q12DC
CPU-V
LCPU
QSCPU
QCPU
(A mode)
QnACPU ACPU FXCPU
Motion
controller
CPU
CC IE Control
CC IE Field
*1 *2 *1
MELSECNET/H
MELSECNET/10
MELSECNET(II)
Ethernet
Computer link
QCPU (Q mode)
(ActCCG4Q, ActMLCCG4Q)
CC-Link
CC IE Control
CC IE Field
*1 *2 *1
MELSECNET/H
MELSECNET/10
MELSECNET(II)
Ethernet
Computer link
Q12DCCPU-V
(ActCCG4Q, ActMLCCG4Q)
CC-Link
CC IE Control
CC IE Field
MELSECNET/H
MELSECNET/10
MELSECNET(II)
Ethernet
Computer link
LCPU
(ActCCG4Q, ActMLCCG4Q)
CC-Link
*
1: Inaccessible to Q12DCCPU-V and QSCPU relayed by CC-Link IE Field Network since CC-Link IE Field Network is not supported.
*2: Inaccessible to LCPU relayed by CC-Link IE Controller Network since CC-Link IE Controller Network is not supported.