8 - 48 8 - 48
MELSOFT
8 ACCESSIBLE DEVICES AND RANGES
8.13.2 Accessible ranges
This section indicates the accessible ranges for Q series bus communication.
(1) Access can be made to another CPU on the same base.
However, access cannot be made to another CPU via the network of another CPU.
(2) Access can be made to another CPU via the MELSECNET/H module controlled
by the PC CPU module.
In this case, the accessible ranges are as in MELSECNET/H communication.
Refer to Section 8.10.2.
The IBM-PC/AT compatible used for MELSECNET/H communication corresponds
to the PC CPU module, and the MELSECNET/H board to the MELSECNET/H
module.
(3) Access can be made to another CPU via the CC-Link module controlled by the PC
CPU module.
In this case, the accessible ranges are as in CC-Link communication. Refer to
Section 8.7.2.
The IBM-PC/AT compatible used for CC-Link communication corresponds to the
PC CPU module, and the CC-Link board to the CC-Link module.