Adjustment Procedures
5-58
2715 Spectrum Analyzer Service Manual
To characterize the test setup, enter the following at the prompt on the PC:
CHAR<Return>
Select device under test (DUT). Both selections need to be run, select 1 or 2 and
return key?
H For split75 select 1 then press <Return>:
Follow the on-screen instructions. You will be prompted to make the
connections shown in Figure 5-- 22 (if you are using a dual channel power
meter) or Figures 5--23 (if you are using a single channel power meter). If
you are using a single channel power meter, midway through the test you
will be prompted to make the connections shown in Figure 5--24. The test
will then run to completion.
H For split50 select 2 then press <Return>:
Follow the on-screen instructions. You will be prompted to make the
connections shown in Figure 5-- 25 (if you are using a dual channel power
meter) or Figures 5--26 (if you are using a single channel power meter). If
you are using a single channel power meter, midway through the test you
will be prompted to make the connections shown in Figure 5--27. The test
will then run to completion.