Adjustment Procedures
2715 Spectrum Analyzer Service Manual
5-59
Signal Generator
Power Meter
50 Ω Cable
Min Loss Pad
N(F)toBNC(M)
50 Ω Power
Sensor
75 Ω Power
Sensor
Power
Divider
75 Ω BNC (F) to BNC (F)
Adapter
6dB
Pad (N)
20 dB
Pad (N)
75 Ω N (F) to BNC (M) Adapter
Figure 5- 22: Test Equipment Characterization Using a Dual Channel Power Meter
for split75
Signal Generator
Power Meter
50 Ω Cable
Min Loss Pad50 Ω Power
Sensor
75 Ω
Termination
Power
Divider
75 Ω BNC (F) to BNC (F)
Adapter
6dB
Pad (N)
20 dB
Pad (N)
Figure 5- 23: Test Equipment Characterization Using a Single Channel Power Meter
to Characterize the Power Meter Output for split75
Signal Generator
Power Meter
50 Ω Cable
Min Loss Pad
N(F)toBNC(M)
50 Ω
Termination
75 Ω Power
Sensor
Power
Divider
75 Ω BNC (F) to BNC (F)
Adapter
6dB
Pad (N)
20 dB
Pad (N)
75 Ω N (F) to BNC (M) Adapter
Figure 5- 24: Test Equipment Characterization Using a Single Channel Power Meter
to Characterize the DUT Output f or split75