NDA-24298 CHAPTER 4
Page 79
Issue 1
ASYD : Assignment of System Data
1
43
b
0
For Remote Access to System, is Forced Account (F/A) Code
Dialing required upon receiving RBT?
0/1 = Required/Not Required
0b
1
Not used
b
2
Send SST after ACC Code dialing for Authorization Code or F/A
code is dialed using LCR Access
0/1 = Out/In Service
0b
3
Not used
b
4
ATT Re-enters Loop on Serial Call
0/1 = Restriction/Allowed
b
5
Send DT to the distant Office upon receiving Terminated Office
Code (Tandem)
0/1 = Not Required/Required
0b
6
Not used
b
7
Restriction for Dialing more than the max. of necessary digits (as
assigned via command AMND)
0/1 = Not Required/Required
Note: If a calling party dials more than the maximum
necessary digits, the calling party receives reorder tone.
44
b
0
Automatic Circuit Assurance
0/1 = Out/In Service
0b
1
Not used
0b
2
0b
3
0b
4
0b
5
0b
6
0b
7
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT