Issue 1
AATC : Assignment of Authorization Code Data
AATC: Assignment of Authorization Code Data
1. General
This command assigns the Authorization Code that is used for Authorization Code/Forced Account Code/Pad
Lock, and Remote Access to system features.
2. Precautions
1. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS 1, INDEX 8. If
data for this command is common for all tenants (ASYD command, SYS1, INDEX 94, bit3=1), assign TN
parameter as data 1 for all tenants.
2. When data 1 (Restricted) is entered in the ACR parameter, the RSC and SFC parameter is specified as
the temporary class. The trunk connection or service feature capability of the temporary class is referred
to by the data of the ARSC command and the ASFC command.
3. When data 2 (Allowed) is entered in the ACR parameter, neither the RSC nor SFC parameter appears.
In this case, the trunk connection or service feature is allowed regardless of the ARSC /ASFC data.
4. A maximum of 10 digits of DC can be entered as the Authorization Code.
5. Assign data 0 (Separate) in bit 6, INDEX93, SYS1 of the ASYD command to specify the maximum
number of digits for the command AMND.
6. Check sum (2 digits) for the Authorization Code can be arranged by the data assignment in INDEX 12,
13, and 14 of the ASYD command.
3. Data Entry Instructions
NUMBER
(TN)
TENANT
DIGIT CODE OF ID (DC)
MAXIMUM 10 DIGITS
AUTHORIZATION
CODE
RESTRICTION
(ACR) 1/2
ROUTE
RESTRICTION
CLASS (RSC)
0-15
SERVICE
FEATURE
CLASS
(SFC)
0-15
REMARKS
ACR
1 = Restricted
2 = Allowed
1
2
These parameters don't need to be entered
when parameter Authorization Code
restriction is 2.