NDA-24298 CHAPTER 4
Page 115
Issue 1
ASYD : Assignment of System Data
1
141
b
0
No Answer Timer for Station Call from
AT T :
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0-15).
This timer applies to
stations for which
C.F.-Don’t Answer
has been set. This
timer assigns the
duration for which
calls being
transferred by the
attendant will ring at
the station before
being forwarded.
Timer Value Setting
is MTC
×
TC sec.
Note: When this
data is 00
Hex, default
data is
automatically
set to 10 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned one of
the following values:
b
6
b
5
b
4
b
6
b
5
b
4
0 00=– 100=–
0 01=– 101=–
0 10=– 110=–
0 11=2 sec.111=8 sec.
b
5
b
6
0
b
7
Not used
142
b
0
Automatic Recall Timer for Call Park
service:
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0-15).
Timer Value Setting
is MTC
×
TC sec.
Note: When this
data is 00
Hex, default
data is
automatically
set to 450 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned one of
the following values:
b
6
b
5
b
4
b
6
b
5
b
4
0 00=– 100=–
0 01=– 101=–
0 10=– 110=–
0 11=2 sec111=8 sec.
b
5
b
6
0
b
7
Not used
143 00
Not used
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT