CHAPTER 4 NDA-24298
Page 880
Issue 1
ACAN : Assignment of CIC Number Between Adjacent Nodes for Local Data Memory
ACAN: Assignment of CIC Number Between Adjacent Nodes for
Local Data Memory
1. General
This command assigns LENS and Fusion Circuit Identification Code (Fusion CIC) numbers on the basis of each
Fusion Point Code (FPC).
2. Precautions
1. Before executing this command, confirm that the following assignments have already been completed:
(a) LSG: 12 (the ACRD command) is assigned to the B-channel Route to which the Fusion CIC belongs.
(b) The trunk data for the Fusion CIC is assigned using the ACTK command.
2. The FCIC given to each B-channel should be identical to the originating node and its adjacent node.
3. The available FCIC (Fusion CIC Number) is 1-4095.
4. For detailed information, see the NEAX2400 IPX Fusion Network System Manual.
3. Data Entry Instructions
FUSION POINT CODE
(FPC)
1-253
REMARKS
FPC
FPC is a unique number
allotted to each node.
Assign FPC of the adjacent node
to this parameter.
Fusion CIC number of
the adjacent node
10
10
10
FUSION CIC NUMBER
(FCIC)
1-4095
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
0
1
2
1
2
3
CONNECTION EQUIPMENT
NUMBER (C_LENS)
FCIC
C_LENS
LENS of the trunk for B-channel
assigned by the ACTK command