NDA-24298 CHAPTER 4
Page 113
Issue 1
ASYD : Assignment of System Data
1138
b
0
Periodic Indication Tone Interval Timer:
Miscellaneous Timer Counter (MTC) is to
be assigned a value from 0 Hex to F Hex
(0-15).
This timer assigns
the interval between
Periodic Indication
Tones, after the first
tone has been sent.
Timer Value Setting
is MTC
+ 1 ×
TC.
Note: When this
data is 00
Hex, default
data is
automatically
set to 3 min
(±30 sec.).
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned one of
the following values:
b
6
b
5
b
4
b
6
b
5
b
4
000=– 100=30 sec.
001=64 msec101=–
010=– 110=–
011=2 sec. 111=–
b
5
b
6
0
b
7
Not used
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT