CHAPTER 4 NDA-24298
Page 530
Issue 1
ARTD : Assignment of Route Class Data
98 CI
ISDN transmitting information
0 = Out of Service
1 = 16-Digit Caller Number Service, Attribute
Information Notification Service, and Calling Sub-
Address Transfer Service
2-15= Not used
99 OID 0 0 0 0 Always assign data 0."
100 TKS 0 0 0 0 Always assign data 0."
101 PAD2
Pad Control Data 2
0-7= For Pad value, See the NEAX2400 IPX Circuit Card
Manual.
PAD value can also be
set by switch setting on
the 8TLT (Long Line
Telephone = TELT) card.
102 TRM 0 0 0 0 Always assign data 0."
103 TRPX 0 0 0 0 Always assign data 0."
104 LDR 0 0 0 0 Always assign data 0."
105 TSC 0 0 0 0 Always assign data 0."
106 SATS 0 0 0 0 Always assign data 0."
107 RVPX 0 0 0 0 Always assign data 0."
108 DQ 0 0 0 0 Always assign data 0."
109 SLOV
Slumber Time Override Service
0 = Out of Service 1 = In Service
110 SDTO
System message automatic output when Connection
Acknowledge signal has not been received.
0 = Out of Service 1 = In Service
111 ADVPRA
ISDN PRI Failure Routing Service
0 = Out of Service 1 = In Service
This data is valid for
dummy routes.
112 IND
Inter-office Name Display
0 = Out of Service 1 = In Service
113 UUI
Information notification between the users
0 = Out of Service 1 = In Service
114 DCH 0 0 0 0 Always assign data 0."
115 CMRT
Common use of Route Numbers of ISDN trunks
0 = Out of Service 1 = In Service
116 PREF 0 0 0 0 Always assign data 0."
117 DFS 0 0 0 0 Always assign data 0."
118 BOB
Broad Band
0=64K 1=N
×
64K
119 HO1CH 0 0 0 0 Always assign data 0."
RT
FUNCTION