CHAPTER 4 NDA-24298
Page 860
Issue 1
AFPD : Assignment of Fusion Tandem PAD Data for LDM
Note:
PAD value differs depending on the specification of each circuit card. As to the detail setting of PAD value
on each circuit card, refer to the Circuit Card Manual or related system manuals.
3
3
3
TYPE OF CONNECTION
(TYPE)
INCOMING ROUTE
CONNECTION
(IC)
INCOMING PAD DATA
(ICPAD)
1-15
OUTGOING
ROUTE
(OG RT) 1-255
OUTGOING PAD DATA
(OGPAD)
1-15
1 - 14 = Note
15 = PAD OFF (0dB)
OGPAD
1 - 14 = Note
15 = PAD OFF (0dB)
ICPAD
Assign the incoming connection
route number
When TYPE = 3 is assigned
IC C_RT
3= C_RT → RT
TYPE
Assign the outgoing route number
OGRT
4
4
TYPE OF CONNECTION
(TYPE)
SERVICE FEATURE
RESTRICTION CLASS
(SFC)
0-15
INCOMING PAD DATA
(ICPAD)
1-15
CONNECTION
ROUTE
(C_RT)
1-1023
OUTGOING PAD DATA
(OGPAD)
1-15
1 - 14 = Note
15 = PAD OFF (0dB)
OGPAD
1 - 14 = Note
15 = PAD OFF (0dB)
ICPAD
Assign Service Feature Class for the
station
When TYPE = 4 is assigned
SFC
4 = STN ←→ C_RT
TYPE
Assign the connection route number
C_RT