NDA-24298 CHAPTER 4
Page 545
Issue 1
ARTDN : Assignment of Route Class Data for NDM
73 KPST
Duration of KP sending
0 = 48 msec. 1 = 56 msec.
2 = 64 msec. 3 = 72 msec.
4 = 80 msec. 5 = 88 msec.
6 = 96 msec. 7 = 104 msec.
8 = 112 msec. 9 = 120 msec.
10 = 128 msec. 11 = 136 msec.
12 = 144 msec. 13 = 152 msec.
14 = 160 msec. 15 = 168 msec.
(In case of MFC)
0 = 12.0 sec. 1 = 5.5 sec.
2 = 7.0 sec. 3 = 8.5 sec.
4 = 10.0 sec. 5 = 11.5 sec.
6 = 13.0 sec. 7 = 14.5 sec.
8 = 16.0 sec. 9 = 17.5 sec.
10 = 20.0 sec. 11 = 22.0 sec.
12 = 24.0 sec. 13 = 26.0 sec.
14 = 28.0 sec. 15 = 30.0 sec.
When the monitor signal
is Reverse and the data is
set to 0, KP sending is
stopped by reserve signal
monitor at the related
distant office.
Note: Use this when
ONSG/INSG =
4.(MF)
74 KPPT
Pause after KP sending
0 = 48 msec. 1 = 56 msec.
5 = 88 msec. 6 = 96 msec.
7 = 104 msec. 8 = 112 msec.
12 = 144 msec. 13 = 152 msec.
14 = 160 msec. 15 = 168 msec.
(In case of MFC)
0 = 12.0 sec. 1 = 5.5 sec.
2 = 7.0 sec. 3 = 8.5 sec.
4 = 10.0 sec. 5 = 11.5 sec.
6 = 13.0 sec. 7 = 14.5 sec.
8 = 16.0 sec. 9 = 17.5 sec.
10 = 20.0 sec. 11 = 22.0 sec.
12 = 24.0 sec. 13 = 26.0 sec.
14 = 28.0 sec. 15 = 30.0 sec.
Note: Use this when
ONSG/INSG =
4.(MF)
75
STC Stop Code
0-11= Not used 12 = MF
13= Not used 14 = DTMF
15= MF (for MF signaling)
Use this when ONSG/
INSG = 4. (MF)
76
MC MP Start Cause
0=As per ST 1=Not used
Always set data 0."
77
MT MF Frequency
0=DTMF (4×4) 1 = MF (2 out of 6)
Use this when ONSG/
INSG = 4.(MF)
78 TONE
TONE Designation for TRK Call Termination
0 = DT 1-15= Not used
This data is effective
when 2 (Second Dial
Tone) is set in ARTDN,
ISGS = 3.
LGRT
1-899
FUNCTION
REMARKS
Note
Note