CHAPTER 4 NDA-24298
Page 178
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
1
576
b
0
Fusion Centralized SMDR Service (Polling Method)
0/1 = No/Yes
b
1
SMDR for Fusion Network station-to-station calls
0/1 = All Station Calls/Fusion Station Calls only
Note: Data valid only when ASYDL Index 512 is set.
Valid for IPX Version 2 software or higher.
b
2
SMDR Interface Type
0/1 = RS232C/LANI
b
3
Output the System Message related to connection
down when the system changeover occurs on LAN
Interface for SMDR.
0/1 = Invalid/Valid
b
4
~
b
7
Not used
577
b
0
~
b
7
FPC (Fusion Point Code) of the Center node (CN) for
the Centralized SMDR (Centralized Billing-Fusion).
FPC: 1-253 (01 Hex-FD Hex.)
Note: Data 01 Hex-FD Hex should be assigned at
the Local Node (LN) for the Centralized
Billing-Fusion. Data “00” must be fixedly
assigned at the Center Node (CN) of
Centralized Billing-Fusion.
578
b
0
Centralized Billing-Fusion output text format of
SMDR A
0/1 = ICS format/IPX format
b
1
~
b
3
Not used
b
4
0/1 = SMDR A Apparatus with LAN interface is not
used/used. Note
b
5
~
b
7
Not used
579
b
0
Centralized Billing-Fusion output text format of
SMDR B
0/1 = ICS format/IPX format
b
1
~
b
3
Not used
b
4
0/1= SMDR B Apparatus with LAN interface is not
used/used. Note
b
5
~
b
7
Not used
Note:
Assign “1” at the node to which SMDR with LAN interface is connected. If not connected, this data setting
is fixed to “0.”
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512 - 1535
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT