NEC NDA-24298 Frozen Dessert Maker User Manual


  Open as PDF
of 1020
 
NDA-24298 CHAPTER 4
Page 149
Issue 1
ASYD : Assignment of System Data
1
288
b
0
Output Port for SMDR A Apparatus
When b
4
= 0 (IOC equipment No. 0)
b
0
= Port 0 b
1
= Port 1 b
2
= Port 2b
3
= Port 3
When b
4
= 1 (IOC equipment No. 1)
b
0
= Port 4 b
1
= Port 5 b
2
= Port 6 b
3
= Port 7
•“1 is to be assigned to each bit corresponding to the Port No.
Note 1, Note 2, Note 3
b
1
b
2
b
3
b
4
0
b
5
Expanded SMDR for A apparatus.
0
b
6
Not used
0
b
7
289
b
0
Fault detection timer of SMDR A
Value for the first digit (min):
(0~9) Hex
A~F Hex: Not used
Timer value ranges
from 1 to 99 min-
utes.
00 Hex: Without
fault detection
Normally, Assign 00
Hex.
b
1
b
2
b
3
b
4
Fault detection timer of SMDR A
Value for the second digit (min):
(0~9) Hex
A~F Hex: Not used
b
5
b
6
b
7
290
b
0
Output Port for SMDR B Apparatus
When b
4
= 0 (IOC equipment No. 0)
b
0
= Port 0 b
1
= Port 1 b
2
= Port 2 b
3
= Port 3
When b
4
= 1 (IOC equipment No. 1)
b
0
= Port 4 b
1
= Port 5 b
2
= Port 6b
3
= Port 7
•“1 is to be assigned to each bit corresponding to the Port No.
Note 1, Note 2, Note 3
b
1
b
2
b
3
b
4
b
5
Expanded SMDR for B apparatus.
b
6
Not used
b
7
Note 1:
Among the SMDR equipment that has the same IOC equipment number, double assignment of the port is
rejected.
Note 2:
The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as
SMDR by AIOC.
Note 3: This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not connected
to the node, this data setting is fixed to 0.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT