NDA-24298 CHAPTER 4
Page 97
Issue 1
ASYD : Assignment of System Data
1
87
Hour data is assigned using a decimal
number (Military Time)
Example: 2:00 a.m. –
This data is
entered as 02.
Example: 2:30 p.m. –
This data is
entered as 14.
Routine Diagnosis
Program Start Time
Note: When both
Index 87 and
Index 88 are
assigned data
“FF” Hex,
the Routine
Diagnosis
Program is
not executed.
88
Minute data is assigned using a deci-
mal number (Military Time)
Example: 2:00 a.m. –
This data is
entered as 00.
Example: 2:30 p.m. –
This data is
entered as 30.
89
0b
0
Main Memory Check (Generic Program Memory)
0/1 = No/Yes
b
1
DM Check (DM = Data Memory)
0/1 = No/Yes
b
2
TSW Active/Standby Changeover for Dual Systems
0/1 = No/Yes
b
3
(For 1-IMG, 4-IMG, IPX-U system)
CPU Active/Standby Changeover for Dual Systems
0/1 = No/Yes
(For IPX-UMG system)
SP ACT/STBY Changeover
0/1 = No/Yes
b
4
Trunk Ineffective Hold Detect
0/1 = No/Yes
b
5
Trunk Ineffective Hold Release
0/1 = No/Yes
b
6
Call Forwarding Memory Clear
0/1 = No/Yes
b
7
Not used
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT