NDA-24298 CHAPTER 4
Page 611
Issue 1
APAD : Assignment of PAD Data
APAD: Assignment of PAD Data
1. General
This command assigns PAD control data for tandem connections, and trunk-to-station connections.
2. Precautions
When KIND = 2 (station) is designated, assign the dummy data to the parameter OGPAD.
3. Data Entry Instructions
The kinds of connections entered
in this parameter are as follows:
1 = Tandem Connection
2 = Station
3 = Outgoing (Not used)
4 = Incoming (Not used)
1 9 1 1
1 1 4 81
0 0
2
KIND
The assignment of this parameter
is required only when KIND = 3
(Outgoing) is designated.
This data should be assigned by
the AMND command.
DC
0 = No APAD Setting
1-14 = Note1 15 = PAD OFF (0dB)
ICPAD/OGPAD
This parameter is not required for the
parameter KIND = 1 (Tandem Connec-
tion).
ICPAD is not required when
assigning KIND as 3 (Outgoing).
SFC
KIND
OF
CONNEC
-TION
(KIND)
1-4
INCOMING
ROUTE
NUMBER
(ICRT)
OUTGOING
ROUTE
NUMBER
(OGRT)
SFC
0-15
DIGIT CODE
(DC)
MAXIMUM 24 DIGITS
INCOM-
ING
PAD
DATA
(ICPAD)
1-15
OUTGO-
ING
PAD
DATA
(OGPAD)
1-15
ICPAD
The parameter OGPAD is not required
when assigning KIND as 4 (Incoming).
OGPAD
Note 1: Switch setting varies depending on the
trunk circuit card. Refer to “Circuit
Card Manual.”