CHAPTER 4 NDA-24298
Page 98
Issue 1
ASYD : Assignment of System Data
1
90
b
0
Not used
b
1
Backup Call Forwarding and Individual Speed Data to HDD
(See Index 304)
0/1 = No/Yes
b
2
Not used
b
3
Residual link detect
0/1 = No/Yes
b
4
LP ACT/STBY Changeover (for IPX-UMG system)
0/1 = No/Yes
b
5
CMP ACT/STBY Changeover (for IPX-UMG system)
0/1 = No/Yes
b
6
Not used
b
7
91
0b
0
Not used
0b
1
b
2
Grades of System Message that can be Registered:
0 0 = Register All System Message Data
0 1 = Register System Message Data higher than grade 1
(SUP, MN, MJ)
1 0 = Register System Message Data higher than grade 2
(MN, MJ)
1 1 = Register System Message Data higher than grade 3
(MJ)
Note: This data is fixed to “00” when Alarm Grade data is
assigned by the ALMG command.
b
3
b
4
External Supplied Clock to TSW
(12.352M-24CH System No. 0)
When one PLO card is
to be mounted:
When two PLO cards
are to be mounted:
b
5
External Supplied Clock to TSW
(12.352M-24CH System No. 1)
b
6
External Supplied Clock to TSW
(12.288M-32CH System No. 0*)
b
7
External Supplied Clock to TSW
(12.288M-32CH System No. 1*)
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
b
3
b
2
b
7
b
6
b
5
b
4
0101
b
7
b
6
b
5
b
4
1111