NDA-24298 CHAPTER 4
Page 105
Issue 1
ASYD : Assignment of System Data
Note: When activating the Password function, assign “b
7
= 1” ONLY after a Password Code has been assigned via com-
mand APSW.
Note: When activating the Password function, assign “b
7
= 1” ONLY after a Password Code has been assigned via
command APSW.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
HEX
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1122
0
b
0
Not used
Data for Port 6 of
the IOC Circuit
Card
0
b
1
0
b
2
0
b
3
Not used0
b
4
0
b
5
0
b
6
Not used
b
7
Password Function (Effective only with
MAT)
0/1 = Out/In Service Note
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 511
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1123
0
b
0
Not used
Data for Port 7 for
the IOC Circuit
Card
0
b
1
0
b
2
0
b
3
Not used0
b
4
0
b
5
0
b
6
Not used
0
b
7
Password function (effective only with MAT)
0/1 = Out/In Service Note