CHAPTER 4 NDA-24298
Page 176
Issue 1
ASYDL : Assignment of System Data into Local DM (LDM)
1
528
b
0
Voice Recognition Services Timer
MTC = 0 - 15 (0h to Fh) seconds
Timer value = MTC × TC
This timer defaults to 30 seconds when 00h is
assigned.
b
1
b
2
b
3
b
4
Timer Class (TC)
b
6
b
5
b
4
b
6
b
5
b
4
b
6
b
5
b
4
0 0 0= -----011=2 sec.110=-----
0 0 1 1 00 =30 sec.111=-----
0 1 0= -----101=------
b
5
b
6
b
7
529
b
0
Parity Check Method for SMDR/MCI with LAN
Interface
b
0
b
1
0 0 = Non-Parity Check
1 0 = Odd Parity Check
0 1 = Even Parity Check
b
1
b
2 ~
b
7
Not used
530
b
0
FCCS Health Check Timer
MTC = 0 - 15 (0h to Fh) Seconds
Timer Value = MTC × TC
This timer defaults to 30 seconds when 00h is
assigned.
b
1
b
2
b
3
b
4
Timer Class (TC)
b
6
b
5
b
4
b
6
b
5
b
4
b
6
b
5
b
4
0 0 0= -----011=2 sec.110=-----
0 0 1= 1 00 =30 sec.111=8 sec.
0 1 0= -----101=5 sec.
b
5
b
6
b
7
Is this timer in service?
0/1 = No/Yes
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512 - 1535
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT