NEC NDA-24298 Frozen Dessert Maker User Manual


  Open as PDF
of 1020
 
CHAPTER 4 NDA-24298
Page 410
Issue 1
ASDT : Assignment of Station Data
ASDT: Assignment of Station Data
1. General
This command assigns/deletes the physical station data.
2. Precautions
1. This command is used for Business application. The AAST/AGST commands are used for Hotel applica-
tion.
2. The ASTN command may be used to change the station number.
3. The ASCL command may be used to change the Class (TEC, RSC, and/or SFC) of the station.
4. The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8.
5. The number of station number (STN) digits is designated by the ASYD command, SYS1, INDEX16.
6. The first digit of the station number (STN) is designated by the ANPD command.
7. The RSC and SFC parameter works in conjunction with the ARSC and ASFC commands respectively.
8. TEC 3 (DP/PB) is to be used in the installation test only. Give the proper TEC to each station before ser-
vice-in.
Note:
If the PB (DTMF) station given TEC 3 tries to make a call to the PB (DTMF) route with the 2nd DT mode,
the call will not be successful.
9. An example of the LENS allocation is shown in Figure 4-2.
10. LSDT (Listup of Station Data) command is used to print out the station data. At this time, ETN (Executive
Tenant Number) data is also printed out.
While some commands share the common TN in office data, others develop separate TN table respec-
tively. In case of adapting common TN for all the commands, the TN actually assigned by the ASDT com-
mand is to be executed.