NDA-24298 CHAPTER 4
Page 169
Issue 1
ASYD : Assignment of System Data
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 - 31
DATA
(DATA)
00 - FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
3
0
b
0
ON Time is to be assigned a value from
1 Hex to F Hex (1~15). (Unit of Time is
Second.)
Timer Value for Ringer
used for Incoming Trunk
Calls (Ringer Pattern 0)
Note: Normally, this
Index is assigned
data 21 Hex.
(1 sec.-ON,
2 sec.-OFF)
b
1
b
2
b
3
b
4
OFF Time is to be assigned a value
from 1 Hex to F Hex (1~15). (Unit of
Time is Second.)
b
5
b
6
b
7
1
b
0
ON Time is to be assigned a value from
1 Hex to F Hex (1~15). (Unit of Time is
Second.)
Timer Value for Ringer
used for Station Calls
(Ringer Pattern 1)
Note: Normally, this
Index is assigned
data 42 Hex.
(2 sec.-ON,
4 sec.-OFF)
b
1
b
2
b
3
b
4
OFF Time is to be assigned a value
from 1 Hex to F Hex (1~15). (Unit of
Time is Second.)
b
5
b
6
b
7
2
b
0
Station Release Timer (TS) is to be
assigned a value from 1 Hex to F Hex
(1~15). (Release timing when
connected to an ORT)
Timer Value Setting is (TS)
×
120 msec.
Note: Normally, this
Index is assigned
data 91 Hex.
(TS = 120 msec.,
TL = 1080 msec.)
b
1
b
2
b
3
b
4
Hooking Timer (TL) is to be assigned a
value from 1 Hex to F Hex (1~15).
(SHF maximum timing)
Timer Value Setting is (TL)
×
120
msec.
b
5
b
6
b
7