CHAPTER 4 NDA-24298
Page 408
Issue 1
AABD : Assignment of Speed Calling Restriction Data
AABD: Assignment of Speed Calling Restriction Data
1. General
This command assigns the Speed Calling system Restriction Data. This data is added to the Service Feature
Class of an individual station assigned to the Speed Calling system in order to restrict it from originating calls.
2. Precautions
1. The Abbreviated Digit Codes (ADC) should already be assigned by the ASPD command.
2. The Speed Calling Override Service must be assigned by the ASYD command, SYS2, Index1, b6=1.
3. The applicable Tenant Number (TN) range is designated by the ASYD command, SYS1, INDEX8.
3. Data Entry Instructions
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
RESTRICTION DATA (RES) is assigned in the
squares where ADC and SFC cross. When
unassigned, RES or the corresponding item is
recognized as “0”(Restricted).
0 = Connection is restricted
1 = Connection is allowed
RES
SPEED
CALLING
CODE (ADC)
MAX. 4
DIGITS
TENANT
NUMBER
(TN)
SERVICE FEATURE CLASS (SFC)
ADC
The Abbreviated Digit Codes (ADC) corresponds
to the data assigned by the ASPD command.