NDA-24298 CHAPTER 4
Page 481
Issue 1
AICD : Assignment of Intercom Data
3. Data Entry Instructions
Enter the Module Group number of
the Intercom group.
MG No.
0 = Automatic Intercom
1 = Manual Intercom
A/M
Enter the Tenant Number of the
Intercom group.
TN
Enter the Intercom member stations
which can receive an Intercom call.
SIG STN
Enter the Intercom member stations
which can originate an Intercom call.
ICM STN
0 = Restricted
1 = Allowed
1
2
3
BCR
Enter a unique number for each Intercom
group with a range from 1 to 50.
G-ID
MODULE
GROUP
NUMBER
(MG No.)
GROUP
ID
NUMBER
(G-ID)
1-50
AUTO/
MANUAL
SIGNALING
(A/M)
0/1
BRIDGE
CALL
RESTRIC-
TION
(BCR)
0/1
INTERCOM
STATION NUMBER
(ICM STN)
SIGNALLING
STATION
NUMBER
(SIG STN)
TENANT
NUMBER
(TN)
No.