EDIT Menu
AWG2021 User Manual
3 Ć55
11. Select Go Back from the sub-menu. The system moves from the Scale...
sub-menu to the previous side menu.
Invert Function. Use Invert... to invert the waveform data in the area specified
with the vertical bar cursors either up/down or left/right. The following diagram
shows the menu configuration for the Invert... item.
Operation (More 2 of 3) Invert...
Invert
Horizontal
Vertical
Go Back
Execute
1. Move the left and right vertical bar cursors to define the editing area for
inversion, then select Invert... from the second page of the side menu (More
2 of 3).
2. Press the Invert button in the sub-menu to select Horizontal.
The Invert selects the direction in which the waveform data between the
vertical bar cursors is inverted.
3. Select Execute from the sub-menu. The waveform is inverted horizontally
with the specified conditions.
Figure 3 -32 shows an example of the waveform before and after it is
inverted horizontally.
AfterBefore
Figure 3 Ć32: Horizontally Inverted Display