Tekxon Technology AWG2021 Ventilation Hood User Manual


 
EDIT Menu
3 Ć116
AWG2021 User Manual
If 6 and 7 are used (2):
Initial Src 0
Initial Code 0
Out[1/0] High/Low
Source Data Pattern Converted Code
077 00000001
076 00000010
177 00000100
176 00001000
067 00010000
066 00100000
167 01000000
166 10000000
In the case of the above conversion, the data will be as follows:
Time -1 0 1 2 3 4 5 6 7 8
Input 0 0 1 0 1 1 0 1 0 0
Pattern 067 076 167 077 176 167 076 166
Importing Waveform or Marker Data as Pattern Data. Import Line Data is used to
import the selected bit data as pattern data. It can be used to perform code
conversion even for waveform data.
The commands in the Import Line Data menu will change depending on
whether or not there is data in the pattern data area. When there is no data, the
Import Line Data command will appear in the sub-menu. When data has been
entered, this command will change to Clear Pattern.
1. Select Set... from the side menu.
2. Select the data to be imported and then use the cursors to specify the
required range.
3. Select Set Pattern from the sub-menu.
4. If pattern data exists, press Clear Pattern button in the sub-menu to clear
the existing data.
5. Select Import Line Data from the sub-menu. The selected bit data will be
read into the pattern data input area.