Tekxon Technology AWG2021 Ventilation Hood User Manual


 
SETUP Menu
3 Ć220
AWG2021 User Manual
2. Press the Source button in the side menu and set it to Internal. The clock
icon shown below will be displayed on the screen.
Since the clock frequency for CH2 depends on the clock frequency for CH1,
set the clock frequency for CH1 first.
3. Use the numeric keys or general purpose knob to set the internal clock
frequency with the Internal Clock item.
The clock frequency can be set in four digits between 10.00 Hz and
250.0 MHz.
To set the CH2 clock frequency:
4. Select Divider from the side menu. The divider icon shown below will be
displayed on the screen.
5. Turn the general purpose knob to set the frequency divider.
The clock frequency for CH2 is determined by setting the value for
frequency division of the CH1 clock. This frequency division setting can be
selected from the multiples of 2 from 1 (2
0
) to 16,777,216 (2
24
). The CH2
clock frequency, after frequency division, is expressed with the four digits
under the frequency division value. Depending on the value of the CH1
clock frequency, it may not be possible to set a large frequency division
ratio. For example, if the CH1 clock frequency is 10 Hz, then the only
frequency division ratio that can be set is 1.
When the CH2 waveform is changed by pressing Waveform Sequence, the
frequency division value is always reset to 1 to give CH2 the same clock
frequency as CH1. If you change the clock frequency for CH1, the frequency
division ratio stays the same and the clock frequency for CH2 changes.