Tekxon Technology AWG2021 Ventilation Hood User Manual


 
Appendix B: Performance Characteristics
BĆ10
AWG2021 User Manual
Table BĆ3: Electrical Characteristics (Cont.)
Characteristics Description
** Add When Option 02 (second channel) installed
** Output within 5%
CH1 + CH2 (value indicated at the lower right box in SETUP menu)
Output can not exceed 5 V
pĆp
.
Frequency Response DC to 30 MHz (-3 dB)
Voltage
AC Power Source
Rating Voltage 100 VAC to 240VAC
Continuous range, CAT II
Range
90VACto250VAC 48Hzto63Hz
90 VAC to 127 VAC 48 Hz to 440 Hz
Maximum Power Consumption 300 W
Maximum Current 4A
Grounding Impedance The impedance for the chassis ground and power plug ground pins is 0.1 W at
30 A.
Primary Circuit Dielectric Voltage withstand Test 1500 V
RMS
, 50 Hz for 15 seconds, without breakdown.
Table BĆ4: Environmental Characteristics
Characteristics Description
Temperature
Operating +10_ Cto+40_ C
Non operating -20_ Cto+60_ C
Relative Humidity
Operating 20% to 80% (No condensation)
Maximum wetĆbulb temperature 29.4_ C
Non operating 5% to 90% (No condensation)
Maximum wetĆbulb temperature 40.0_ C
Altitude
Operating To 4.5 km (15000 ft).
Maximum operating temperature decreases 1_ C each 300 m above 1.5 km.
Non operating To 15 km (50000 ft).