Tekxon Technology AWG2021 Ventilation Hood User Manual


 
EDIT Menu
AWG2021 User Manual
3 Ć103
Figure 3 Ć79: Gray Code Pattern Display
Example of Waveform Data Creation. In the following operation, you will replace
the data between the vertical bar cursors with a Count Up pattern, with the
waveform point size set to 4096.
1. Select Standard Waveform from the bottom menu.
2. Press the CURSOR button on the front panel. Using the general purpose
knob, move the left and right vertical bar cursors all the way to the left and
right, respectively, so the entire editing area is selected.
3. Select Pattern from the side menu, then select Count Up by turning the
general purpose knob or pressing the Pattern button in the side menu.
4. Select Step from the side menu. Using the numeric keys or the general
purpose knob, set the step to 1.
5. Select Max from the side menu. Using the numeric keys or the general
purpose knob, set the end point for the Count Up pattern to 4095.
6. Select Min from the side menu. Using the numeric keys or the general
purpose knob, set the starting point for the Count Up pattern to 0.
7. Select Execute from the side menu.
The data between the vertical bar cursors will be replaced by the Count Up
pattern that you have designated. Figure 3 -78 shows the Count Up pattern
created with the values used in this example.