Appendix A: Options and Accessories
AĆ6
AWG2021 User Manual
must be ≤ than 1ns.
waveform to go from 10%
to 90% of its peak value ;
measure the time for the
Rise Time / Fall Time :
Raise Time
Fall Time
Skew : Measure at 50% level of the waveform;
must be ≤ than 1ns.
Clock
Data
Level High : -0.735V -1.02V
Level Low: -1.6V -1.95V
Figure AĆ5: Output Waveform
If a cable is used, these waveforms have transmission distortion. It is necessary
to latch the data with a clock before using the waveform in actual circuits at the
cable receiving side (user side) and to reproduce the waveform. Delay the clock
with the delay line in order to reproduce the data reliably (see Figure A-6).
12 12
Data
Latch
Clock
Buffer
Delay Line
4ns
Buffer
12