Tekxon Technology AWG2021 Ventilation Hood User Manual


 
Appendix B: Performance Characteristics
AWG2021 User Manual
BĆ9
Table BĆ3: Electrical Characteristics (Cont.)
Characteristics Description
Auxiliary Input
** TRIGGER
** Accuracy ±(5% of Level + 0.1 V)
Pulse Width 15 ns minimum
Input Swing 0.2 V
pĆp
minimum
Maximum Input Volts 10 V
pĆp
when 1 MW selected
5V
RMS
when 50 W selected
Trigger to Signal delay
Internal Clock 100 ns maximum
External Clock 100 ns maximum + 0.5 Clock + 1 Clock maximum
Trigger Holdoff 1 ms maximum (Excluding Autostep mode)
AM
Amplitude Accuracy within 5%
Maximum Input Volts ±5V
** CLOCK
** Threshold Level 0.5 V
Input Swing 0.8 V
pĆp
minimum
Pulse Width 2 ns minimum
Maximum Input Volts ±2V
Frequency Range 250 MHz maximum
AM and ADD
AM (Multiply) When Option 02 (second channel) installed
Output
within 5%
CH2 Signal 5 V 100%
0V 0%
-5 V -100%
Frequency Response DC to 30 MHz (-3 dB)
** External AM
** Sensitivity 2 V
pĆp
(±5%) signal causes 100% modulation.
Ext Signal ă1 V 100% modulation
ă0 V 50% modulation
-1 V 0% modulation
Frequency Response
CH1 DC to 30 MHz (-3 dB)
External Signal DC to 4 MHz (-3 dB)