NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Analog Communications Interface (ACI)
Aspire Software Manual Features 91
Default Setting
No PGDAD modules programmed.
Programming
10-03-01 : PCB Setup - Terminal Type (Circuit 1)
10-03-06 : PCB Setup - Terminal Type (Circuit 2)
The circuit should be assigned a type “9” for ACI or type “7”for an external ringer.
10-05-01 : General Purpose Relay Setup
Dene which relay circuits (5-8) on the 2PGDAD Module are used for General Purpose
Relays. Also refer to Program 10-21-01 for the NTCPU relay assignments.
10-07-01 : Conversation Record Circuits
Assign the number of conversation record circuits.
10-21-01 : NTCPU Hardware Setup - External Source Control Switch Selection on
NTCPU
Specify the function of the relay switch for external tone source control (0=external MOH
source, 1=BGM source, 2=external speaker (Aspire only), 3=general purpose relay). If this is
set to 2, service code 803+1 pages and the relay closes. The relay opens upon hang up. If this
option is set to ‘3’, service code 880+0 toggles the relay open or closed. Also refer to Program
10-05-01 for PGDAD Module relay assignments.
11-06-01 : ACI Extension Numbering
Assign extension numbers to ACI software ports. Select a number outside of the normal
extension number range.
Aspire S: ACI Ports 1-8
Aspire: ACI Ports 1-96
11-08-01 : ACI Group Pilot Number
Assign pilot numbers to ACI groups. When a user dials the pilot number, they reach an avail-
able ACI software port within the group.
Aspire S: ACI Groups 1-4
Aspire: ACI Groups 1-16
11-12-50 : Service Code Setup (For Service Access)
Specify the service code to be used for toggling the relay open and closed (Default: 880).
PGDAD/ACI Interface Specications
Relay Contacts
Maximum Contact Ratings 30 V DC @ 60 mA
90 V AC @ 10 mA
Minimum Application Load 1 V DC @ 1 mA
Audio/Music Input
Input Impedance 47 K Ohms @ 1 KHz
Audio/Paging Output
Output Impedance 600 Ohms @ 1 KHz
Maximum Output + 8 dBm