NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Program 10 : System Conguration Setup
10-03 : PCB Setup
732 Programming Aspire Software Manual
Note 1. The start port number of a PRI line is displayed. Thirty logic ports are automatically
assigned to a PRI line.
Note 2. Each timer value of Layer3 is set up for each type in Program 81-06 (T-Bus) and Pro-
gram 82-06 (S-Bus).
13 Loss-Of-Signal detection limit In short-haul mode In long-haul mode
0 = 0.91V 0 = 1.70V
1 = 0.74V 1 = 0.84V
2 = 0.59V 2 = 0.84V
3 = 0.42V 3 = 0.45V
4 = 0.32V 4 = 0.45V
5 = 0.21V 5 = 0.20V
6 = 0.16V 6 = 0.10V
7 = 0.10V 7 = not dened
0
14 Service Protocol for S-Point 0 = Keypad Facility
1 = Specied Protocol for Aspire System
0
15 Alert Tone When S-Bus Terminal
Calls Busy Extension
This option determines for S-Bus ter-
minals what a user on an S-Bus ter-
minal will hear when a busy
extension is called. If this option is
set to "0", the user will hear an alert
tone. If this option is set to "1", the
user will be disconnected.
0 = Alert Tone
1 = Disconnected
0
16 ISDN 2 B-Channel Transfer
Enable or disable the 2 B-Channel
Transfer function for a PRI PCB.
0 = Off/Disable
1 = On/Enable
0
18 Type of Number
Use this option to dene the ISDN
numbering plan to allow the calling
party information to be passed to
some telcos. Note that with soft-
ware 4.08-4.0W, Program 99-01-32
was used instead.
0 = Unknown
1 = International number
2 = National number
3 = Network Specic number
4 = Subscriber number
5 = Abbreviated number
3
19 Numbering Plan Identication
passed to some telcos. Note that
with software 4.08-4.0W, Program
99-01-33 was used instead.
0 = Unknown
1 = ISDN numbering plan
2 = Data numbering plan
3 = Telex numbering plan
4 = National standard numbering plan
5 = Private numbering plan
1
Item
No.
Item Input Data Default