Program 14 : Trunk, Basic Setup
14-01 : Basic Trunk Data Setup
Aspire Software Manual Programming 873
Program 14 : Trunk, Basic Setup
14-01 : Basic Trunk Data Setup
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for each trunk port. Refer
to the chart below for a description of each option, its range and default setting.
Input Data
Level:
Aspire S Aspire M/L/XL
IN
Available. Available.
Item 24 available with software 2.63+.
Item 25 available with software 4.0E+.
Item 26 available with software 4.93+.
Item 27 available with software 4.93+.
Item 24 available with software 2.63+.
Item 25 available with software 4.0E+.
Item 26 available with software 4.93+.
Item 27 available with software 4.93+.
Trunk Port Number Aspire S: 1-8
Aspire: 001-200
Item
No.
Item Input Data Default
Related
Program
01 Trunk Name
Set the names for trunks. The trunk name
displays at display keysets for incoming
and outgoing calls.
Up to 12 characters 1 = Line 001
|
Line 200 = Line 200
02 Transmit CODEC Gain Type
Use this option to select the CODEC gain
for the trunk. The option sets the amount
of gain (signal amplication) for the trunk
you are programming.
1~63
(-15.5 ~ +15.5dB in
.5dB intervals)
32 (0dB)
03 Receive CODEC Gain Type
Use this option to select the CODEC gain
for the trunk. The option sets the amount
of gain (signal amplication) for the trunk
you are programming.
1~63
(-15.5 ~ +15.5dB in
.5dB intervals)
32 (0dB)
04 Transmit Gain Level for Conference
and Transfer Calls
Use this option to select the CODEC gain
type used by the trunk when it is part of an
Unsupervised Conference.
1~63
(-15.5 ~ +15.5dB in
.5dB intervals)
22 (-5dB)
05 Receive Gain Level for Conference and
Transfer Calls
Use this option to select the CODEC gain
type used by the trunk when it is part of an
Unsupervised Conference.
1~63
(-15.5 ~ +15.5dB in
.5dB intervals)
22 (-5dB)