NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Flash
332 Features Aspire Software Manual
Flash
Description
Flash allows an extension user to access certain CO and PBX features by interrupting trunk loop
current. Flash lets an extension user take full advantage of whatever features the connected telco or
PBX offers. You must set the Flash parameters for compatibility with the connected telco or PBX.
Conditions
The system does not provide a ground ash.
Default Setting
Enabled.
Programming
14-02-03 : Analog Trunk Data Setup - Flashing/Grounding
Make sure this item is set for open loop Flash (0).
14-02-04 : Analog Trunk Data Setup - Flash for Timed Flash or Disconnect
For each trunk, indicate if Flash is for Flash (0) or open loop disconnect (1).
15-02-05 : Multi-Line Telephone Basic Data Setup - Transfer Key Operation Mode
If the CONF key should access Flash, enter 2. Otherwise, enter 0 or 1.
In order for the Cordless Lite/Cordless Lite II phone user to be able to use the ash function
(ex: to use the Door Box relay), this option must be set to “2”. This changes the Transfer key
to a Flash key.
15-02-24 : Multi-Line Telephone Basic Data Setup - Conference Key Mode
This option allows an extension’s CONF key to be programmed for Conference or for Transfer.
15-03-04 : Single Line Telephone Basic Data Setup - Flashing
In a single line (500/2500 type) telephone’s Class of Service, enable (1) or disable (0) the abil-
ity to hookash for system feature access.
81-01-14 : COIU Initial Data Setup - Hookash 1
Set the Flash duration (16-4080mS) for analog trunk (COIU PCB) circuits.
81-01-15 : COIU Initial Data Setup - Hookash 2
Set the open loop disconnect duration (16-4080mS) for analog trunk (COIU PCB) circuits.
Aspire S Aspire M/L/XL
Available. Available.