Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
Aspire Software Manual Programming 1397
Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
Description
Use Program 81-01 : COIU Initial Data Setup to dene the various basic timers for COIU PCBs.
Input Data
Level:
Aspire S Aspire M/L/XL
MF
Available. Available.
Item 12 renamed to Caller ID Detection
Time with software 4.93+.
Item 12 renamed to Caller ID Detection
Time with software 4.93+.
Item
No.
Item Input Data Default
01 Companding Method Type 0 = u-law
1 = A-law
0 (u-law)
02 Loop Current Detection Time 1-255 (8-2040mS) 75 (600ms)
03 Clear Signal (Open Loop) Detection Time 1-255 (8-2040mS) 90 (720ms)
04 Ringing Signal Detection Minimum Time 1-255 (8-2040mS) 13 (104ms)
05 Single Ringing Detection Minimum Time 0-255 (0,8-2040mS) 82 (656ms)
06 Double Ringing Detection Minimum off Time 0-255 (0,8-2040mS) 13 (104ms)
07 Double Ringing Detection Maximum off Time 0-255 (0,8-2040mS) 50 (400ms)
08 Ringing Signal Not Detected Minimum 1-255 (8-2040mS) 88 (704ms)
09 Abandoned Call Detection Timer 1-255 (64-16320mS) 94 (6016ms)
10 Continuous Ringing Minimum Time 0-255 (0,8-2040mS) 38 (304ms)
11 Continuous Ringing Maximum Time 0-255 (0,8-2040mS) 88 (704ms)
12 Prior to 4.93 Software: AC Impedance Timer
Software 4.93+: Caller ID Detection Time
If an entry other than "0" is made, the actual waiting time is the value x
64ms. For example, if the timer is set to 46, the COIU waits 46 x 64ms
= 2944ms). If a problem exists with Caller ID displaying, the recom-
mended entry to try rst would be "46".
Prior to 4.93 Soft-
ware: 1-255
(64-16320mS)
Software 4.93+:
0 = COIU waits
500ms from end of
rst ring to begin-
ning of FSK signal
for Caller ID
1 - 255 = The COIU
waits for the Caller
ID FSK signal from
when the rst ring
pulse was detected.
Prior to 4.93
Software: 4
(256ms)
Software
4.93+: 0
13 Grounding Time 1-255 (4-1020mS) 9 (36ms)