NEC 5 Wok User Manual


  Open as PDF
of 1614
 
Program 81 : Basic Hardware Setup for Trunk
81-02 : DIOPU Initial Data Setup
1400 Programming Aspire Software Manual
81-02 : DIOPU Initial Data Setup
Description
Use Program 81-02 : DIOPU Initial Data Setup to dene the various basic timers for the DIOPU
cards.
Input Data
Level:
Aspire S Aspire M/L/XL
MF Available. Available.
Item
No.
Item Input Data Default
01 Companding method type 0 = u-law
1 = A-law
0 (u-law)
02 Answer Signal Time 1-255 (4-1020mS) 6 (24ms)
03 Clear Signal (Open Loop) Detection Time 1-255 (100-25500mS) 7 (700ms)
04 Ringing Signal Detection Min. Time 1-255 (8-20240mS) 10 (80ms)
05 Hook Flash Time 1-255 (8-20240mS) 25 (200ms)
06 Pause Time 1-255 (1-255 Seconds) 94 (94 Sec)
07 WINK/DELAY Duration Time 1-255 (8-20240mS) 20 (160ms)
08 Incoming-WINK/DELAY Send Time 1-255 (100-25500mS) 3 (300ms)
09 Seizure-WINK/DELAY Receive Max. Time 1-255 (100-25500mS) 48 (4800ms)
10 Receive WINK/DELAY Duration Min. Time 1-255 (8-20240mS) 13 (104ms)
11 Receive WINK/DELAY Duration Max. Time 1-255 (8-20240mS) 31 (248ms)
12 Receive DP Make Min. Time 1-255 (4-1020mS) 5 (20ms)
13 Receive DP Make Max. Time 1-255 (4-1020mS) 50 (200ms)
14 Receive DP Break Min. Time 1-255 (4-1020mS) 5 (20ms)
15 Receive DP Break Max. Time 1-255 (4-1020mS) 50 (200ms)
16 Receive DP Inter-Digit Time 1-255 (8-20240mS) 6 (48ms)
17 Loop Off Guard Time 0-255 (0,100-25500mS) 20 (2000ms)
18 DP Break Time (10pps) 1-255 (4-1020mS) 16 (64ms)
19 DP Make Time (10pps) 1-255 (4-1020mS) 8 (32ms)
20 DP Inter-Digit Time (10pps) 1-255 (100-25500mS) 38 (3800ms)
21 DP Break Time (0pps) 1-255 (4-1020mS) 8 (32ms)
22 DP Make Time (20pps) 1-255 (4-1020mS) 4 (16ms)
23 DP Inter-Digit Time (20pps) 1-255 (100-25500mS) 29 (2900ms)