Program 25 : VRS/DISA Setup
25-07 : System Timers for VRS/DISA
Aspire Software Manual Programming 1127
25-07 : System Timers for VRS/DISA
Description
Use Program 25-07 : System Timers for VRS/DISA to set the value for the system timers which
affect DID and DISA. Refer to the following chart for a description of each option, its range and
default setting.
Input Data
Level:
Aspire S Aspire M/L/XL
IN
Available. Available.
Options 07 and 08 enhanced with software
4.0E+.
Options 07 and 08 enhanced with software
4.0E+.
Item
No.
Item Input Data Default
Related
Program
01 DISA Dial Tone Time
After answering a DISA trunk, the system waits this interval for the
caller to dial the rst digit of the DISA password. If the caller fails
to dial within this interval, the system drops the call.
0-64800
seconds
10 25-04
02 VRS/DISA No Answer Time
A VRS/DISA caller can ring an extension for this interval before
the system sets the call as a Ring No Answer. After this interval
expires, the call follows the programmed Ring No Answer routing
(set in Program 25-03 and 25-04).
0-64800
seconds
30 25-04
03 Disconnect after VRS/DISA re-transfer to IRG 0-64800
seconds
60
04 Calling Time to Automatic Answering Telephone Set
Set the answering waiting time of the automatic answering exten-
sion when an incoming DID trunk call is received.
0-64800
seconds
10
05 Duration Time for Guidance Message by Automatic Answering
Telephone Set
Set the announcement time of the automatic answering extension
after which in incoming DID trunk caller is disconnected.
0-64800
seconds
10
06 Duration Time for Guidance Message by ACI
Set the announcement time by the ACI after which an incoming
DID trunk caller is disconnected.
0-64800
seconds
10
07 Long Conversation Warning Tone Time
Determine the length of time a DISA caller or any trunk-to-trunk
(such as Tandem Trunking) conversation can talk before the Long
Conversation tone is heard.
With software 4.0E+, if Program 25-07-08 is set to "0", the call is
disconnected once the timer expires. This timer is set again when
the external digit timer expires.
Note: If this option is set to "0", the settings in Program 24-02-07
and 24-07-10 are followed - not 25-07-07 and 25-07-08.
0-64800
seconds
180 24-02-07
24-07-10
25-07-08